Vertical jump testing: technologies and devices compared

Countermovement jump, drop jump and hop test: what each technology can measure, how closely it agrees with force plates in published studies, and what it costs.

Last updated 17 November 2026

Jump height is the easy part.

Most technologies report it. Contact time, reactive strength index and countermovement timing are where they separate.

Check which jump height.

Height from take-off and height from standing are different numbers. Standing-based methods read several centimetres higher.

Contact time varies most.

Published bias against force plates runs from a few milliseconds to over 40 ms, and reactive strength index inherits it.

Agreement belongs to the device.

Two devices using the same technology can agree very differently with force plates. Check the device, not the category.

What each technology can measure

TechnologyJump heightContact timeReactive strength indexCountermovement timingForceNothing worn or attachedAutomatic
Force platesVALD ForceDecks, Hawkin Dynamics
Jump and reachVertec
Contact matsJust Jump, Plyomat, SmartJump
Photocells and lasersOptoJump, OVR Jump, G-Flight
Wearable sensorsOutput Sports, Enode
Linear position transducersGymAware
Phone apps, frames marked by handMy Jump Lab, Kinovea
Phone apps, automaticMy Jump Lab, automatic mode
Metra PerformanceiPhone app, automatic

YesOn some devices, or for some testsNo

From each maker’s published specifications, November 2026. Countermovement timing means time to take-off and the measures built on it, such as RSI-modified. Metra Performance reports mean propulsive and mean landing force as estimates; it does not measure force.

Agreement with force plates

Each row is one published study, except the Metra Performance rows, which are our own testing. The bar is the range that 95 % of single jumps fell within, compared with the force plate: the 95 % limits of agreement (Bland and Altman, 1986). A short bar centred on the line is what you want.

Jump height, countermovement jump

Height measured from take-off, like the force plate

OptoJumpPhotocells. Glatthorn et al., 2011
−1.9 to −0.1 cm95 % limits
G-FlightPhotocells. Parmar et al., 2021
+0.6 to +16.9 cm95 % limits

Devices that measure height from standing

VertecJump and reach. Buckthorpe et al., 2012
−9.0 to +4.2 cm95 % limits
GymAwareLinear position transducer on a waist belt. Wadhi et al., 2018
+2.8 to +14.6 cm95 % limits

Metra Performance, our own testing

Metra Performance, countermovement jumpiPhone app. 23 athletes, 109 jumps
−1.8 to +1.8 cm95 % limits

Published as an average difference only, with no limits: My Jump Lab, automatic mode +1.0 cm (Şentürk et al., 2025); G-Flight +3.2 cm (Watkins et al., 2020); Just Jump +13 cm (McMahon et al., 2016).

Ground contact time, drop jump and hop test

Published studies

Contact mat24 cm drop, the largest bias of three drop heights. Tenelsen et al., 2019
−7.2 to +13.4 ms95 % limits
KinoveaVideo, frames marked by hand. Watkins et al., 2020
−43.0 to +67.0 ms95 % limits
My Jump 2Phone app, frames marked by hand. Haynes et al., 2019
−5.5 to +33.8 ms95 % limits
Output SportsWearable sensor. Montoro-Bombú et al., 2022
−44.0 to +127.0 ms95 % limits

Metra Performance, our own testing

Metra Performance, drop jumpiPhone app. 21 athletes, 101 jumps
−15.1 to +13.7 ms95 % limits
Metra Performance, hop testiPhone app. 22 athletes, 180 hops
−11.3 to +11.1 ms95 % limits

Published as an average difference only, with no limits: G-Flight +7.0 ms (Watkins et al., 2020); PUSH band −10.0 ms (Watkins et al., 2020).

Read each row on its own: the studies used different athletes, protocols and drop heights, so this is not a head-to-head trial. Some limits were calculated from values the studies report. A second My Jump Lab study found +0.9 cm (−2.7 to +4.4) across unloaded and loaded jumps together (Balsalobre-Fernández and Varela-Olalla, 2024). The Metra Performance rows are our own testing, which is not yet peer reviewed. Vertec was compared with a force plate height measured from standing, and GymAware with one measured from take-off, so GymAware’s difference includes the rise onto the toes. One further contact mat read 10.5 % low for drop jump contact time (Rogan et al., 2015). No peer-reviewed validation of OVR Jump was found as of November 2026.

The technologies

Force plates

They measure force directly, and everything else is calculated from it: jump height, contact time, reactive strength index, the timing of each phase, and left-right differences on dual plates. Every other device on this page is judged against them.

Examples
VALD ForceDecks, Hawkin Dynamics
Cost
Usually a subscription or lease in the thousands of US dollars a year. Some plates are sold outright.

Jump and reach

The athlete touches the highest vane they can, and height is that reach minus standing reach. It measures from standing and depends on reach technique, so it is a different number from flight-time jump height.

Examples
Vertec
Cost
From about US$750

Contact mats

A switch mat times how long the feet are off it and on it. That gives jump height from flight time, contact time and, on some mats, reactive strength index. A mat cannot see when the movement starts, so it gives no countermovement timing. Published agreement varies a lot from one mat to another.

Examples
Just Jump, Plyomat, SmartJump
Cost
Just Jump and Plyomat about US$850 to US$1,000. SmartJump is sold on subscription

Photocells and lasers

A beam at floor level is broken while the feet are down. The measures are the same as a mat, with nothing to land on. OptoJump has some of the closest published agreement with force plates for jump height.

Examples
OptoJump, OVR Jump, G-Flight
Cost
OVR Jump and G-Flight about US$299. OptoJump from about €3,500

Wearable sensors

A small motion sensor worn on the body estimates the jump. Convenient across many exercises, but each athlete has to wear it, and published contact time agreement ranges from close to poor depending on the device.

Examples
Output Sports, Enode
Cost
Sensor plus an annual licence

Linear position transducers

A cable clipped to a belt or bar tracks how far and how fast it travels. Built for bar speed. For jumps it reports height from standing, which reads higher than flight-time height. GymAware adds drop jump contact time and reactive strength index through its cloud software.

Examples
GymAware
Cost
Supplier quote

Phone apps, frames marked by hand

You film the jump, then mark the take-off and landing frames yourself. Jump height correlates very highly with reference devices. The cost is time: every repetition has to be marked, which slows a squad session. Kinovea is free desktop video software with a stopwatch, not a jump app.

Examples
My Jump Lab, Kinovea
Cost
A few US dollars a month. Kinovea is free

Phone apps, automatic

The app finds take-off and landing itself, so the result appears without marking anything. My Jump Lab’s automatic mode is published for countermovement jump height. Metra Performance covers jump height, contact time, reactive strength index and countermovement timing.

Examples
My Jump Lab, Metra Performance
Cost
My Jump Lab a few US dollars a month. Metra Performance is not released yet; the plan is free testing, with a subscription for athlete profiles and tracking over time

This is not a complete list. Other options include further makes of force plate, mat and wearable sensor, markerless camera systems such as VALD HumanTrak, and sensor insoles such as Plantiga. Prices are approximate, from makers’ and resellers’ websites in November 2026.

Choosing

If you needForce itself

Force, impulse, rate of force development or left-right differences in a two-leg jump: force plates. Nothing else measures them.

If you needJump height, contact time and reactive strength index across a squad

Photocells or an automatic phone app. Look for agreement data on the specific measures you will use, not only jump height.

If you testJump and reach

Keep those results in their own record. Reach height and flight-time height are not interchangeable.

Whatever you choose, keep each athlete on one device, one protocol and one arm position. For tracking change over time, a consistent device matters more than which device it is. Agreement with force plates matters when you compare against norms or against another device.

Metra Performance

An iPhone app that analyses each jump automatically and shows the result live. No cloud processing, no calibration, no manual frame picking, no wearables.

−1.8 to +1.8 cmJump height against force plates, countermovement jump. 95 % limits of agreement.
−15.1 to +13.7 msContact time against force plates, drop jump.
−0.17 to +0.16Reactive strength index (flight time ÷ contact time) against force plates, drop jump.
  • Tests: countermovement jump, drop jump and hop test, hands on hips. Single-leg tests, squat jump and loaded jump are in beta.
  • Measures: jump height (flight time), flight time, contact time, reactive strength index, contraction time, RSI-modified and countermovement depth.
  • Cost and availability: the beta opens in early 2027. The plan is free testing, with a subscription for athlete profiles and tracking over time.

Our own testing against force plates with 23 athletes. Relative error (RMSE) was 1.2 to 4.0 % across 16 measures (dynamic rebound index not included), with ICC 0.97 to 0.99. It is not yet peer reviewed; a study is in preparation. Every measure is in the validation summary.

Get early access

More: Jump tests · Validation summary · Metric definitions · Jump test norms

Sources
  1. Balsalobre-Fernández, C., & Varela-Olalla, D. (2024). The validity and reliability of the My Jump Lab app for the measurement of vertical jump performance using artificial intelligence. Sensors, 24(24), 7897. doi.org/10.3390/s24247897
  2. Bland, J. M., & Altman, D. G. (1986). Statistical methods for assessing agreement between two methods of clinical measurement. The Lancet, 327(8476), 307–310. doi.org/10.1016/S0140-6736(86)90837-8
  3. Buckthorpe, M., Morris, J., & Folland, J. P. (2012). Validity of vertical jump measurement devices. Journal of Sports Sciences, 30(1), 63–69. doi.org/10.1080/02640414.2011.624539
  4. Glatthorn, J. F., Gouge, S., Nussbaumer, S., Stauffacher, S., Impellizzeri, F. M., & Maffiuletti, N. A. (2011). Validity and reliability of Optojump photoelectric cells for estimating vertical jump height. Journal of Strength and Conditioning Research, 25(2), 556–560. doi.org/10.1519/JSC.0b013e3181ccb18d
  5. Haynes, T., Bishop, C., Antrobus, M., & Brazier, J. (2019). The validity and reliability of the My Jump 2 app for measuring the reactive strength index and drop jump performance. The Journal of Sports Medicine and Physical Fitness, 59(2), 253–258. doi.org/10.23736/S0022-4707.18.08195-1
  6. McMahon, J. J., Jones, P. A., & Comfort, P. (2016). A correction equation for jump height measured using the Just Jump system. International Journal of Sports Physiology and Performance, 11(4), 555–557. doi.org/10.1123/ijspp.2015-0194
  7. Montoro-Bombú, R., Field, A., Santos, A. C., & Rama, L. (2022). Validity and reliability of the Output sport device for assessing drop jump performance. Frontiers in Bioengineering and Biotechnology, 10, 1015526. doi.org/10.3389/fbioe.2022.1015526
  8. Parmar, A., Keenan, A., & Barry, G. (2021). Concurrent validity of the portable gFlight system compared to a force plate to measure jump performance variables. Physiological Measurement, 42(1), 015003. doi.org/10.1088/1361-6579/abd236
  9. Rogan, S., Radlinger, L., Imhasly, C., Kneubuehler, A., & Hilfiker, R. (2015). Validity study of a jump mat compared to the reference standard force plate. Asian Journal of Sports Medicine, 6(4). doi.org/10.5812/asjsm.25561
  10. Şentürk, D., Yüksel, O., & Akyildiz, Z. (2025). The concurrent validity and reliability of the My Jump Lab smartphone app for the real-time measurement of vertical jump performance. Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology, 239(3), 559–566. doi.org/10.1177/17543371241246439
  11. Tenelsen, F., Brueckner, D., Muehlbauer, T., & Hagen, M. (2019). Validity and reliability of an electronic contact mat for drop jump assessment in physically active adults. Sports, 7(5), 114. doi.org/10.3390/sports7050114
  12. Wadhi, T., Rauch, J. T., Tamulevicius, N., Andersen, J. C., & De Souza, E. O. (2018). Validity and reliability of the GymAware linear position transducer for squat jump and counter-movement jump height. Sports, 6(4), 177. doi.org/10.3390/sports6040177
  13. Watkins, C. M., Maunder, E., van den Tillaar, R., & Oranchuk, D. J. (2020). Concurrent validity and reliability of three ultra-portable vertical jump assessment technologies. Sensors, 20(24), 7240. doi.org/10.3390/s20247240